Guides · Sommer twist M
Sommer twist M troubleshooting and LED indicators
Search by LED or symptom, including SH, Safety, remote control and gate movement.
Work on the control, operator and safety devices must be carried out by qualified personnel. Isolate the supply and secure against restarting before work. Follow the manufacturer’s instructions, including battery isolation and capacitor discharge times where applicable. Stop using a system with faulty safety devices or uncontrolled movement.
Use the manual for your exact control version. The following guidance helps to identify the affected area before a professional inspection. Manufacturer manual (PDF)
Last updated: November 2026 · torautomation24 editorial team · Based on the official manufacturer manual · Installation manual (PDF)
Control LEDs
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| Netz LED off | Supply may be missing | Have the incoming supply, fuses and voltage during starting checked by an electrician. | — |
| SH flashing rapidly | Stored values may be invalid or jumper changed after learning | Record whether a power failure or jumper change preceded the fault. A specialist should determine whether reset and new learning runs are needed. | — |
| Netz + Safety on | Photocell beam may be interrupted | Check the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists. | — |
| Netz + AUF/ZU on | A command device may supply a continuous signal | Check whether another command device works. Have the push button, contacts and cable checked. | — |
| Receiver LED does not respond | Radio signal not received or receiver not working | Check the battery and compare with a second learned transmitter. Have the antenna and receiver checked if range remains poor. | — |
Remote controls and push buttons
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| Transmitter LED off | Battery flat, incorrectly inserted or transmitter faulty | Check battery type, polarity and condition. If a new battery does not help, have the transmitter checked. | — |
| Short range only | Weak battery or poor reception | Check the battery and compare with a second learned transmitter. Have the antenna and receiver checked if range remains poor. | — |
| Button works, transmitter does not | Transmitter unlearned or incompatible radio system | Have operating mode, configuration and commissioning checked against the manual. | — |
| Pedestrian opening does not respond | Partial-opening transmitter button may not be learned | Have operating mode, configuration and commissioning checked against the manual. | — |
| Key switch does not respond | Contact, switch or wiring faulty | Check whether another command device works. Have the push button, contacts and cable checked. | — |
Gate movement
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| Gate does not open | Drive released, gate obstructed, frozen or electric lock engaged | Check for visible obstructions, ice, snow and an unreleased lock. If the motor hums without movement, switch the system off immediately. | — |
| Gate does not close | Photocell, supply or radio fault | Check the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists. | — |
| Gate stops and reverses | Obstacle detection, safety edge, photocell, wind or stiff hinges | Have the door checked for stiffness, blockages, spring damage, imbalance and wind load before altering force settings. | — |
| Gate does not reach limit position | Limit switch or mounting bracket incorrectly set | Have A/B mounting dimensions, brackets and limit-switch settings checked against the installation manual. | — |
| Uneven gate movement | Mounting dimensions may differ | Have A/B mounting dimensions, brackets and limit-switch settings checked against the installation manual. | — |
| Operator hits pillar | Mounting dimensions or limit position incorrect | Have A/B mounting dimensions, brackets and limit-switch settings checked against the installation manual. | — |
| Incorrect closing sequence | Leaf operator assignment may be incorrect | Have active and passive leaf assignment checked against the wiring diagram. | — |
| Gate does not stop at obstacle | Learning mode or unsuitable force settings | Take the system out of service. Have force limitation and safety devices tested by a qualified technician. | — |
| Force values not learned | Control may not be prepared for learning run | Have operating mode, configuration and commissioning checked against the manual. | — |
Fault memory and restart
Record which LEDs are lit or flashing and whether the fault followed a power failure, jumper change or learning run. A reset may require new force-learning runs and a professional safety check. Follow the commissioning chapter for the exact variant.
Frequently asked questions
Does a fault code identify a defective part?
It identifies the affected function or circuit. Wiring, adjustment, supply and mechanics can cause similar messages. Have the cause checked before replacing a component.
Which information should I send with a compatibility enquiry?
Send the rating plate, control part number, supply voltage, software version where available and the full fault message. For radio issues, include transmitter and receiver details.
Can I acknowledge or reset a fault immediately?
Resolve the cause first. Reset procedures and learning runs vary by model, and a factory reset may erase settings. Follow the manual for the installed version.