Skip to main content Skip to search Skip to main navigation
Your partner for trades, industry, and commercial customers
Visit us Online!
Go to homepage

Guides · Hörmann A445

Hörmann A445 error codes and troubleshooting

A two-digit number with a flashing dot indicates a fault. Enter the number below.

Work on the control, operator and safety devices must be carried out by qualified personnel. Isolate the supply and secure against restarting before work. Follow the manufacturer’s instructions, including battery isolation and capacitor discharge times where applicable. Stop using a system with faulty safety devices or uncontrolled movement.

Use the manual for your exact control version. The following guidance helps to identify the affected area before a professional inspection. German manufacturer reference

Last updated: November 2026 · torautomation24 editorial team · Based on the official manufacturer manual · Installation manual (PDF) (German)

Skip product gallery

Controls and compatible spare parts

Hormann Replacement PCB for Door Control A445
€359.00*
plus VAT

in stock

Hormann absolute encoder AWG with screw A/B 435/ A/B 445/ A/B 460
€127.00*
plus VAT

delivery time: 3-5 working days

Hormann Door Control A 445 complete in Enclosure
€749.00*
plus VAT

in stock

Closed-circuit safety chain

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
01Closed-circuit safety loop openHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
02Safety-edge closed-circuit loop openRecord the yellow LED state at the safety-edge box. Have the coiled cable, wicket-door contact and locking bolts checked.—
03Drive safety loop at X40 openHave motor overheating and the emergency-operation mechanism checked.—
04Closed-circuit loop at X50 openCheck the miniature key-switch position. If the fault remains, have the cover and connection checked.—

Safety devices and force limitation

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
11Safety edge at X30 activated or test failedCheck for obstacles and dirty optics. Record the red LED at the safety-edge box; have optosensors and coiled cable tested.—
12Safety device at X20 activated or test failedCheck beam alignment. Have the wiring and the specified version-P Y connector checked.—
13Safety device at X21 activated or test failedCheck beam alignment. Have the wiring and the specified version-P Y connector checked.—
14Safety device at X22 activated or test failedCheck beam alignment. Have the wiring and the specified version-P Y connector checked.—
158k2 safety edge at X30 activated or test failedRecord the red LED state. Have the resistive edge and coiled cable checked.—
16Wicket-door contact test failedHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
17Opening force limit activatedHave stiffness and spring balance checked first. The technician can then review programme menu 05.—
18Closing force limit activatedHave closing movement checked for stiffness. After spring work, have programme menu 06 checked as well.—

Door movement and operator

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
21Motor does not startHave door stiffness, motor coupling, motor cable and fuse checked.—
22Incorrect motor directionStop the system. Have motor direction, mains phase sequence, encoder assignment and brake operation checked by qualified personnel.—
23Motor speed too lowHave the door checked for stiffness, blockages, spring damage, imbalance and wind load before altering force settings.—
24Operator unsuitable for door typeHave door height, transmission ratio, operator rating and chain-box installation checked.—
32Maximum running time exceededHave door height, transmission ratio, operator rating and chain-box installation checked.—

Electronics, communication and memory

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
31Power circuit-board faultHave the exact control version identified and the circuit board tested before selecting a replacement.Buy ›
33Force measurement faultHave main-circuit fuses and the power board checked. The manual also identifies board replacement as a possible remedy.Buy ›
34Force measurement faultHave main-circuit fuses and the power board checked. The manual also identifies board replacement as a possible remedy.Buy ›
3524 V undervoltageHave external loads checked for overload and short circuits.—
41Communication fault at X40Have the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components.Buy ›
42Communication fault at X50Have the cover-keypad plug and connecting cable checked.—
43Communication fault at X51Have the module, bus wiring, plugs and power supply checked. Record recurring interruptions.—
46EEPROM test failedAccording to the manual, stored functions require reprogramming after power is restored. Have configuration and commissioning checked.—
47RAM test failedThe manual describes restoration of temporary data at power-up. Have recurring faults investigated.—
48ROM test failedIf the fault returns after restarting, have the control tested.—

Fault memory and restart

Service menu 01 displays the last ten faults. Open the selected menu with STOP and use the CLOSE button to browse. Record the codes and their order. The manual explains entry into service mode. A flashing L requests a learning run.

Frequently asked questions

Does a fault code identify a defective part?

It identifies the affected function or circuit. Wiring, adjustment, supply and mechanics can cause similar messages. Have the cause checked before replacing a component.

Which information should I send with a compatibility enquiry?

Send the rating plate, control part number, supply voltage, software version where available and the full fault message. For radio issues, include transmitter and receiver details.

Can I acknowledge or reset a fault immediately?

Resolve the cause first. Reset procedures and learning runs vary by model, and a factory reset may erase settings. Follow the manual for the installed version.

All guides · Ask about compatibility