Guides · Hörmann A445
Hörmann A445 error codes and troubleshooting
A two-digit number with a flashing dot indicates a fault. Enter the number below.
Work on the control, operator and safety devices must be carried out by qualified personnel. Isolate the supply and secure against restarting before work. Follow the manufacturer’s instructions, including battery isolation and capacitor discharge times where applicable. Stop using a system with faulty safety devices or uncontrolled movement.
Use the manual for your exact control version. The following guidance helps to identify the affected area before a professional inspection. German manufacturer reference
Last updated: November 2026 · torautomation24 editorial team · Based on the official manufacturer manual · Installation manual (PDF) (German)
Closed-circuit safety chain
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| 01 | Closed-circuit safety loop open | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| 02 | Safety-edge closed-circuit loop open | Record the yellow LED state at the safety-edge box. Have the coiled cable, wicket-door contact and locking bolts checked. | — |
| 03 | Drive safety loop at X40 open | Have motor overheating and the emergency-operation mechanism checked. | — |
| 04 | Closed-circuit loop at X50 open | Check the miniature key-switch position. If the fault remains, have the cover and connection checked. | — |
Safety devices and force limitation
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| 11 | Safety edge at X30 activated or test failed | Check for obstacles and dirty optics. Record the red LED at the safety-edge box; have optosensors and coiled cable tested. | — |
| 12 | Safety device at X20 activated or test failed | Check beam alignment. Have the wiring and the specified version-P Y connector checked. | — |
| 13 | Safety device at X21 activated or test failed | Check beam alignment. Have the wiring and the specified version-P Y connector checked. | — |
| 14 | Safety device at X22 activated or test failed | Check beam alignment. Have the wiring and the specified version-P Y connector checked. | — |
| 15 | 8k2 safety edge at X30 activated or test failed | Record the red LED state. Have the resistive edge and coiled cable checked. | — |
| 16 | Wicket-door contact test failed | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| 17 | Opening force limit activated | Have stiffness and spring balance checked first. The technician can then review programme menu 05. | — |
| 18 | Closing force limit activated | Have closing movement checked for stiffness. After spring work, have programme menu 06 checked as well. | — |
Door movement and operator
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| 21 | Motor does not start | Have door stiffness, motor coupling, motor cable and fuse checked. | — |
| 22 | Incorrect motor direction | Stop the system. Have motor direction, mains phase sequence, encoder assignment and brake operation checked by qualified personnel. | — |
| 23 | Motor speed too low | Have the door checked for stiffness, blockages, spring damage, imbalance and wind load before altering force settings. | — |
| 24 | Operator unsuitable for door type | Have door height, transmission ratio, operator rating and chain-box installation checked. | — |
| 32 | Maximum running time exceeded | Have door height, transmission ratio, operator rating and chain-box installation checked. | — |
Electronics, communication and memory
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| 31 | Power circuit-board fault | Have the exact control version identified and the circuit board tested before selecting a replacement. | Buy › |
| 33 | Force measurement fault | Have main-circuit fuses and the power board checked. The manual also identifies board replacement as a possible remedy. | Buy › |
| 34 | Force measurement fault | Have main-circuit fuses and the power board checked. The manual also identifies board replacement as a possible remedy. | Buy › |
| 35 | 24 V undervoltage | Have external loads checked for overload and short circuits. | — |
| 41 | Communication fault at X40 | Have the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components. | Buy › |
| 42 | Communication fault at X50 | Have the cover-keypad plug and connecting cable checked. | — |
| 43 | Communication fault at X51 | Have the module, bus wiring, plugs and power supply checked. Record recurring interruptions. | — |
| 46 | EEPROM test failed | According to the manual, stored functions require reprogramming after power is restored. Have configuration and commissioning checked. | — |
| 47 | RAM test failed | The manual describes restoration of temporary data at power-up. Have recurring faults investigated. | — |
| 48 | ROM test failed | If the fault returns after restarting, have the control tested. | — |
Fault memory and restart
Service menu 01 displays the last ten faults. Open the selected menu with STOP and use the CLOSE button to browse. Record the codes and their order. The manual explains entry into service mode. A flashing L requests a learning run.
Frequently asked questions
Does a fault code identify a defective part?
It identifies the affected function or circuit. Wiring, adjustment, supply and mechanics can cause similar messages. Have the cause checked before replacing a component.
Which information should I send with a compatibility enquiry?
Send the rating plate, control part number, supply voltage, software version where available and the full fault message. For radio issues, include transmitter and receiver details.
Can I acknowledge or reset a fault immediately?
Resolve the cause first. Reset procedures and learning runs vary by model, and a factory reset may erase settings. Follow the manual for the installed version.