Guides · FEIG TST FUZ-2Cx
FEIG TST FUZ-2Cx error codes and troubleshooting
Search by the complete F code, including any final letter, or by symptom. This guide covers 48 selected messages.
Work on the control, operator and safety devices must be carried out by qualified personnel. Isolate the supply and secure against restarting before work. Follow the manufacturer’s instructions, including battery isolation and capacitor discharge times where applicable. Stop using a system with faulty safety devices or uncontrolled movement.
Use the manual for your exact control version. The following guidance helps to identify the affected area before a professional inspection. German manufacturer reference
Last updated: November 2026 · torautomation24 editorial team · Based on the official manufacturer manual · Data sheet (PDF) (German)
Position and travel
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| F.000 | Upper position limit exceeded | Have the upper end position and mechanical brake checked. | — |
| F.005 | Lower position limit exceeded | Have the closed end position and braking behaviour checked. | — |
| F.020 | Running time exceeded | Have the door path, blockages, limit switches and configured running time checked. | — |
| F.021 | Emergency-opening test failed | Record the code and operating conditions and contact a qualified service technician. | — |
| F.030 | Position changes less than expected | Have mechanics, brake, motor and position encoder checked. | — |
| F.031 | Detected rotation direction differs | Stop the system. Have motor direction, mains phase sequence, encoder assignment and brake operation checked by qualified personnel. | — |
| F.033 | Position-encoder data disturbed | Have the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components. | — |
| F.060 | Collision detected | Stop the system and have the curtain and mechanics checked for impact damage. | — |
| F.061 | Belt-break signal | Keep the system out of service and have the belt and its monitoring checked. | — |
Safety circuits and sensors
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| F.043 | Photocell pre-limit switch inconsistent | Have the limit-switch system, wiring, reference and stored end positions checked against the installation manual. | — |
| F.201 | Internal emergency stop or processor monitoring | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| F.211 | External emergency-stop input 1 interrupted | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| F.212 | External emergency-stop input 2 interrupted | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| F.320 | Obstacle during opening | Check the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists. | — |
| F.325 | Obstacle during closing | Check the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists. | — |
| F.360 | Short circuit at safety-edge input | Have the safety edge, coiled cable, connectors, water ingress and configured sensor type checked. | — |
| F.361 | Too many activations of safety evaluator D | Have the safety edge, coiled cable, connectors, water ingress and configured sensor type checked. | — |
| F.362 | Redundant evaluator signals differ | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
| F.380 | Short circuit at safety input | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| F.383 | Safety input interrupted | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
| F.384 | Safety-input test failed | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
| F.38A | 8k2 wicket-door contact redundancy fault | Have the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved. | — |
Supply, electronics and service
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| F.080 | Service interval reached | Arrange maintenance of the door system. | — |
| F.090 | Basic configuration missing | Have operating mode, configuration and commissioning checked against the manual. | — |
| F.400 | Hardware restart detected | Have the module, bus wiring, plugs and power supply checked. Record recurring interruptions. | — |
| F.401 | Processor watchdog triggered | Record the code and operating conditions and contact a qualified service technician. | — |
| F.40A | Internal software fault | Record the code and operating conditions and contact a qualified service technician. | — |
| F.40B | Expansion-board communication fault | Have the module, bus wiring, plugs and power supply checked. Record recurring interruptions. | — |
| F.410 | Motor or DC-link overcurrent | Have mechanical resistance, motor rating, motor data and load checked. | — |
| F.420 | DC-link overvoltage | Have mains supply, regenerative braking energy and brake chopper checked. | — |
| F.425 | Mains voltage too high | Have the incoming supply, fuses and voltage during starting checked by an electrician. | — |
| F.426 | Mains voltage too low | Have the incoming supply, fuses and voltage during starting checked by an electrician. | — |
| F.524 | External 24 V missing or too low | Have external loads checked for overload and short circuits. | — |
| F.535 | Enclosure temperature too high | Allow the system to cool. Have ambient temperature, installation conditions and duty cycle checked. | — |
Light curtains, encoders and radio modules
| Code or observation | Meaning / possible cause | Checks and next steps | Buy spare parts |
|---|---|---|---|
| F.601 | Light-curtain reception too weak | Check the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists. | — |
| F.610 | Light-line calibration missing | Have operating mode, configuration and commissioning checked against the manual. | — |
| F.612 | Light-curtain RS485 communication disturbed | Have the module, bus wiring, plugs and power supply checked. Record recurring interruptions. | — |
| F.621 | Light-curtain transmitter self-test failed | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
| F.622 | Light-curtain receiver self-test failed | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
| F.700 | Position sensing implausible | Have the limit-switch system, wiring, reference and stored end positions checked against the installation manual. | — |
| F.701 | Closing position not detected in timer mode | Have the closed end position and braking behaviour checked. | — |
| F.702 | Opening position not detected in timer mode | Have the upper end position and mechanical brake checked. | — |
| F.752 | Limit-switch communication disturbed | Have the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components. | — |
| F.760 | Position outside expected window | Have the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components. | — |
| F.767 | TST PD encoder temperature too high | Allow the system to cool. Have ambient temperature, installation conditions and duty cycle checked. | — |
| F.768 | TST PD backup battery weak | Identify the unit and battery type. Replace batteries according to the relevant unit manual; for WSD, also check for battery passivation. | — |
| F.801 | Mobile TST FSx input 1 test failed | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
| F.80A | Stationary unit input A test failed | Have the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty. | — |
Fault memory and restart
Correct the cause before acknowledging a fault. For faults without automatic acknowledgement, the FEIG manual specifies holding STOP for about five seconds. Record recurring codes and operating conditions for the service technician.
Frequently asked questions
Does a fault code identify a defective part?
It identifies the affected function or circuit. Wiring, adjustment, supply and mechanics can cause similar messages. Have the cause checked before replacing a component.
Which information should I send with a compatibility enquiry?
Send the rating plate, control part number, supply voltage, software version where available and the full fault message. For radio issues, include transmitter and receiver details.
Can I acknowledge or reset a fault immediately?