FEIG TST FUZ-2Cx error codes and troubleshooting

Search by the complete F code, including any final letter, or by symptom. This guide covers 48 selected messages.

Work on the control, operator and safety devices must be carried out by qualified personnel. Isolate the supply and secure against restarting before work. Follow the manufacturer’s instructions, including battery isolation and capacitor discharge times where applicable. Stop using a system with faulty safety devices or uncontrolled movement.

Use the manual for your exact control version. The following guidance helps to identify the affected area before a professional inspection. German manufacturer reference

Last updated: November 2026 · torautomation24 editorial team · Based on the official manufacturer manual · Data sheet (PDF) (German)

Position and travel

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
F.000Upper position limit exceededHave the upper end position and mechanical brake checked.—
F.005Lower position limit exceededHave the closed end position and braking behaviour checked.—
F.020Running time exceededHave the door path, blockages, limit switches and configured running time checked.—
F.021Emergency-opening test failedRecord the code and operating conditions and contact a qualified service technician.—
F.030Position changes less than expectedHave mechanics, brake, motor and position encoder checked.—
F.031Detected rotation direction differsStop the system. Have motor direction, mains phase sequence, encoder assignment and brake operation checked by qualified personnel.—
F.033Position-encoder data disturbedHave the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components.—
F.060Collision detectedStop the system and have the curtain and mechanics checked for impact damage.—
F.061Belt-break signalKeep the system out of service and have the belt and its monitoring checked.—

Safety circuits and sensors

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
F.043Photocell pre-limit switch inconsistentHave the limit-switch system, wiring, reference and stored end positions checked against the installation manual.—
F.201Internal emergency stop or processor monitoringHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
F.211External emergency-stop input 1 interruptedHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
F.212External emergency-stop input 2 interruptedHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
F.320Obstacle during openingCheck the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists.—
F.325Obstacle during closingCheck the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists.—
F.360Short circuit at safety-edge inputHave the safety edge, coiled cable, connectors, water ingress and configured sensor type checked.—
F.361Too many activations of safety evaluator DHave the safety edge, coiled cable, connectors, water ingress and configured sensor type checked.—
F.362Redundant evaluator signals differHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—
F.380Short circuit at safety inputHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
F.383Safety input interruptedHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—
F.384Safety-input test failedHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—
F.38A8k2 wicket-door contact redundancy faultHave the affected safety circuit, contact, cable and termination checked. Keep the system out of service until the fault is resolved.—

Supply, electronics and service

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
F.080Service interval reachedArrange maintenance of the door system.—
F.090Basic configuration missingHave operating mode, configuration and commissioning checked against the manual.—
F.400Hardware restart detectedHave the module, bus wiring, plugs and power supply checked. Record recurring interruptions.—
F.401Processor watchdog triggeredRecord the code and operating conditions and contact a qualified service technician.—
F.40AInternal software faultRecord the code and operating conditions and contact a qualified service technician.—
F.40BExpansion-board communication faultHave the module, bus wiring, plugs and power supply checked. Record recurring interruptions.—
F.410Motor or DC-link overcurrentHave mechanical resistance, motor rating, motor data and load checked.—
F.420DC-link overvoltageHave mains supply, regenerative braking energy and brake chopper checked.—
F.425Mains voltage too highHave the incoming supply, fuses and voltage during starting checked by an electrician.—
F.426Mains voltage too lowHave the incoming supply, fuses and voltage during starting checked by an electrician.—
F.524External 24 V missing or too lowHave external loads checked for overload and short circuits.—
F.535Enclosure temperature too highAllow the system to cool. Have ambient temperature, installation conditions and duty cycle checked.—

Light curtains, encoders and radio modules

Code or observationMeaning / possible causeChecks and next stepsBuy spare parts
F.601Light-curtain reception too weakCheck the travel area from a safe position. With the system stopped, check for dirty or obstructed optics. Have alignment, wiring and function checked if the fault persists.—
F.610Light-line calibration missingHave operating mode, configuration and commissioning checked against the manual.—
F.612Light-curtain RS485 communication disturbedHave the module, bus wiring, plugs and power supply checked. Record recurring interruptions.—
F.621Light-curtain transmitter self-test failedHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—
F.622Light-curtain receiver self-test failedHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—
F.700Position sensing implausibleHave the limit-switch system, wiring, reference and stored end positions checked against the installation manual.—
F.701Closing position not detected in timer modeHave the closed end position and braking behaviour checked.—
F.702Opening position not detected in timer modeHave the upper end position and mechanical brake checked.—
F.752Limit-switch communication disturbedHave the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components.—
F.760Position outside expected windowHave the encoder or limit-switch cable, connectors, signal and mechanical coupling checked before replacing components.—
F.767TST PD encoder temperature too highAllow the system to cool. Have ambient temperature, installation conditions and duty cycle checked.—
F.768TST PD backup battery weakIdentify the unit and battery type. Replace batteries according to the relevant unit manual; for WSD, also check for battery passivation.—
F.801Mobile TST FSx input 1 test failedHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—
F.80AStationary unit input A test failedHave the connected safety device, supply, wiring and test signal checked. Keep the system out of service if protection is faulty.—

Fault memory and restart

Correct the cause before acknowledging a fault. For faults without automatic acknowledgement, the FEIG manual specifies holding STOP for about five seconds. Record recurring codes and operating conditions for the service technician.

Frequently asked questions

Does a fault code identify a defective part?

It identifies the affected function or circuit. Wiring, adjustment, supply and mechanics can cause similar messages. Have the cause checked before replacing a component.

Which information should I send with a compatibility enquiry?

Send the rating plate, control part number, supply voltage, software version where available and the full fault message. For radio issues, include transmitter and receiver details.

Can I acknowledge or reset a fault immediately?

Resolve the cause first. Reset procedures and learning runs vary by model, and a factory reset may erase settings. Follow the manual for the installed version.

All guides · Ask about compatibility